Specifications
|
Size Range |
0.10 - 1.0 μm |
0.2 - 2μm |
0.3 - 25μm |
0.5 - 25μm |
0.3 - 25μm |
0.5 - 25μm |
0.2 - 2μm |
0.3 - 25μm |
0.5 - 25μm |
0.3 - 25μm |
0.5 - 25μm |
Channel Sizes |
Standard: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0 μm |
Standard: 0.2, 0.3μm
Standard: 0.2, 0.5μm |
Standard: 0.3, 0.5μm
Standard: 0.3, 1.0μm
Standard: 0.3, 3.0μm |
Standard: 0.5, 5.0μm
Standard: 0.5, 10.0μm |
Standard: 0.3, 0.5μm
Standard: 0.3, 1.0μm
Standard: 0.3, 3.0μm |
Standard: 0.5, 5.0μm
Standard: 0.5, 10.0μm |
Standard: 0.2, 0.3μm
Standard: 0.2, 0.5μm
Optional: 0.2, 0.3, 0.5, 1.0μm
Optional: 0.2, 0.3, 0.5, 2.0μm |
Standard: 0.3, 0.5μm
Standard: 0.3, 1.0μm
Standard: 0.3, 3.0μm
Optional: 0.3, 0.5, 1.0, 5.0μm |
Standard: 0.5, 5.0μm
Optional: 0.5, 1.0, 5.0, 10.0μm
Optional: 0.5, 5.0, 10.0, 25.0μm |
Standard: 0.3, 0.5μm
Optional: 0.3, 0.5, 0.7, 1.0μm; 0.3, 0.5, 1.0, 5.0μm;
Optional: 0.3, 0.5, 5.0, 10.0μm |
Standard: 0.5, 5.0μm; 0.5, 10.0μm
Optional: 0.5, 1.0, 5.0, 10.0μm; 0.5, 5.0, 10.0, 25.0μm |
Standard: 0.5, 5.0μm;
Optional: 0.5, 10.0; 0.5, 25.0 μm |
Standard: 0.5, 5.0 µm
Optional 4 Channels: 0.5, 1.0, 5.0, 25.0 µm |
Counting Efficiency |
50% @ 0.1 μm; 100% for particles > 0.15 μm (per JIS) |
50% @ 0.2μm; 100% for particles > 0.3μm (per JIS) |
50% @ 0.3μm; 100% for particles > 0.45μm (per JIS) |
50% @ 0.5μm; 100% for particles > 0.75μm (per JIS) |
50% @ 0.3μm; 100% for particles > 0.45μm (per JIS) |
50% @ 0.5μm; 100% for particles > 0.75μm (per JIS) |
50% @ 0.2μm; 100% for particles > 0.3μm (per ISO 21501-4) |
50% @ 0.3μm; 100% for particles > 0.45μm (per ISO 21501-4) |
50% @ 0.5μm; 100% for particles > 0.75μm (per ISO 21501-4) |
50% @ 0.3 μm; 100% for particles > 0.45 μm (per ISO 21501-4) |
50% @ 0.5 μm; 100% for particles > 0.75 μm (per ISO 21501-4) |
Flow Rate |
1.0 CFM (28.3 LPM) |
0.1 CFM (2.83 LPM) |
1.0 CFM (28.3 LPM) |
0.1 CFM (2.83 LPM) |
1.0 CFM (28.3 LPM) |
Laser Source |
Long Life Laser Diode |
Laser Diode |
Zero Count Level |
<1 count / 5 minutes (per JIS) |
< 1 count / 5 minutes (per ISO 21501-4) |
Concentration Limits |
500,000 Particles / ft3 (17,150,000 / m3) @ 5% Coincidence Loss, per ISO 21501-4 |
2,000,000 Particles / ft3 @ 5% Coincidence Loss |
500,000 Particles / ft3 @ 5% Coincidence Loss |
Calibration |
NIST Traceable, per ISO 21501-4 |
NIST Traceable |
Vacuum Requirements |
External Vacuum required, nominal 1.0 CFM >18" (45.72 cm) of Hg |
External Vacuum >18” (45.72 cm) of Hg |
Air Flow |
- |
Internally Monitored |
Critical Orifice controlled |
Internally Monitored |
Communication Modes |
RS 485 MODBUS |
4-20mA |
RS-485 MODBUS |
4-20mA |
RS-485/MODBUS |
LED Indicators |
Power, Flow, Service, Sampling |
Power, Service |
Power, Flow, Service, Sampling |
Power, Service |
Power, Flow, Service, Sampling |
Data Storage |
- |
Rotating Buffer, 2000 Records |
- |
Rotating Buffer, 2000 Records |
Supporting Software |
Lighthouse Monitoring System, LMS Express, LMS Express RT, LMS Express RT Plus |
Lighthouse Monitoring System |
LMS XChange, Lighthouse Monitoring System; LMS Express; Express RT; LMSNet |
Environmental Sensors |
- |
(Optional) Temperature/Relative Humidity Probe 32 - 122F (0-50C)+/-1F (0.5C); 0 - 100% RH +/-2% |
- |
External Alarm Output |
- |
Normally Open (NO), Dry-contact, Rated 0-60 VDC/VAC, 1 Amp |
- |
Connector |
|
Screw Terminal |
RJ45 |
Industrial RJ45 |
Enclosure |
Stainless steel |
316L Stainless Steel, Wash Down Resistant |
316L Stainless Steel, Wash Down Resistant/Splash-Tight |
VHP Compatible |
- |
Yes |
Power |
24 VDC |
Dimensions |
10.5” (w) x 7.65” (h) x 3.35” (d) [26.67 x 19.43 x 8.51 cm] |
1.7”(l) x 4.2”(w) x 2.5”(h) [4.3 x 10.7 x 6.3 cm] |
3.5"(l) x 4.2"(w) x 3.3"(h) [8.89 x 10.66 x 8.38 cm] |
1.7"(l) x 4.2"(w) x 3"(h) [4.3 x 10.7 x 7.6 cm] |
5.4” (l) x 4.6” (h) x 1.65” (d) [13.72 x 11.68 x 4.19 cm] |
4.2" (l) x 2.0" (w) x 3.7" (h) [10.7 x 5.08 x 9.398 cm] |
Weight |
7.0 lb (3.18 kg) |
0.78 lb (0.35 kg) |
0.97 lb (0.44 kg) |
2 lb (0.90 kg) |
0.97 lb (0.44 kg) |
17.3 oz (0.49 kg) |
15.6 oz (0.44 kg) |
Environmental Conditions
|
Operating |
50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing |
Storage |
14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing |
Accessories
|
Included |
Operating Manual, Purge Filter, Power Supply, Power Cord |
Operating Manual on CD |
Optional |
Isokinetic Sampling Probe, Sample Tubing, Cabling |
Printed Operating Manual; Isokinetic Sampling Probes; Vacuum Tubing; Sample Tubing; Data Cable; Purge Filter; Power Supply; High-Pressure Diffuser (not available for 2012); RS-232 Interface cable and adapter; USB to Serial Port Converter; REMOTE Mounting Bracket. |
Printed Operating Manual; RS-485 Hub with Power Supply; RS-232 Communication Cable and Adapter; USB to Serial Port Converter; Network Adapter; Wireless Network Adapter; Isokinetic Sampling Probes; Vacuum Tubing; Sample Tubing; Data Cable; Purge Filter; Power Supply; Temperature/ Relative Humidity Probe; 8’ T/RH Probe Extension Cable; REMOTE Mounting Bracket; LMS XChange, LMS Express; Express RT, LMSNet software; RS-485 Communication Kit; High-Pressure Diffuser (not available for 2014) |
Isokinetic Sampling Probe, Sample Tubing, Cabling, Purge Filter, RS-485 Hub |