LPC 0.1 μm (MODBUS) |
LPC 0.1 µm (4-20mA) |
LPC 0.2 μm (MODBUS) |
LPC 0.2 μm (4-20mA) |
LPC 0.3 μm (MODBUS) |
LPC 0.3 μm (4-20mA) |
LPC 0.5 μm (MODBUS) |
LPC 0.5 μm (4-20mA) |
Specifications
|
Size Range |
0.1 – 0.5 µm |
0.1 – 0.5 µm |
0.2 – 2.0 µm |
0.2 –2.0 µm |
0.3 – 3.0 µm |
0.3 – 3.0 µm |
0.5 – 100.0 µm |
0.5 – 100.0 µm |
Channel Sizes |
Standard: 0.1, 0.2, 0.3, 0.5 µm |
Standard: 0.1, 0.2μm;
Optional: 0.1, 0.3µm; 0.1, 0.5µm |
Standard: 0.2, 0.3, 0.5, 1.0μm; 0.2, 0.5, 1.0, 2.0μm |
Standard: 0.2, 0.3μm
Optional: 0.2, 0.5μm; 0.2, 1.0μm; 0.2, 2.0μm |
Standard: 0.3, 0.5, 0.7, 1.0μm; 0.3, 0.5, 1.0, 3.0μm |
Standard: 0.3, 0.5μm
Optional: 0.3, 0.7μm; 0.3, 2.0μm; 0.3, 3.0μm |
Standard: 0.5, 0.7, 1.0, 2.0μm; 0.5, 1.0, 2.0, 3.0μm; 0.5, 1.0, 2.0, 5.0μm |
Standard: 0.5, 1.0μm
Optional: 0.5, 2.0μm; 0.5, 5.0μm |
Laser Source |
Laser Diode |
Flow Rate |
100ml/min |
Calibration |
NIST Traceable |
Data Storage |
Rotating Buffer, 2000 Records |
- |
Rotating Buffer, 2000 Records |
- |
Rotating Buffer, 2000 Records |
- |
Rotating Buffer, 2000 Records |
- |
Communication Modes |
RS-232 via RJ45 to PC, RS485/Modbus |
RS-232 via RJ45 to PC, 4-20mA |
RS-232 via RJ45 to PC, RS485/Modbus |
RS-232 via RJ45 to PC, 4-20mA |
RS-232 via RJ45 to PC, RS485/Modbus |
RS-232 via RJ45 to PC, 4-20mA |
RS-232 via RJ45 to PC, RS485/Modbus |
RS-232 via RJ45 to PC, 4-20mA |
LED Indicators |
Power, Service, Sampling |
Power and Service |
Power, Service, Sampling |
Power, Service |
Power, Service, Sampling |
Power, Service, Sampling |
Power, Service, Sampling |
Power, Service, Sampling |
Supporting Software |
LMS Express, Express RT and RT+, LMSNet |
Concentration Limit |
64,000 counts/ml @ 5% Coincidence Error |
4,000 counts/ml @ 5% Coincidence Error |
External Alarm Output |
Normal Open Dry Contact Rated 0 – 60v AC/DC 1 Amp |
Enclosure |
Stainless Steel |
Sample Inlet/Outlet Connection |
1/4" Flaretek™ |
Sample Temperature |
32 - 302°F (0 – 150 °C) |
Sample Pressure |
150 PSI |
Wetted Surface Materials |
Quartz, PTFE, PFA |
Power |
24V DC |
Dimensions |
5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm] |
Weight |
3.5 lbs (1.58 kg) |
Environmental Conditions
|
Operating |
50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing |
Storage |
14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing |
Accessories
|
Included |
Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Cleaning Brush |
Operating Manual on CD; Power Supply; Flow Cell cleaning brush; Micro90® solution; tubing. |
Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush |
Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution |
Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush |
Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution |
Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush |
Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution |
Optional |
Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT; LMSNet software |
Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. |
Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software |
Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. |
Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software |
Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. |
Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software |
Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. |